Launched on 6 October 2026Last updated on

Aortic stent grafts: TEVAR and EVAR

Sets the indication for an aortic stent graft and its alternative. Abdominal: AAA repair from 55 mm in men and 50 mm in women, with growth or symptoms; EVAR within the device instructions for use (neck length, diameter and angulation, iliac access), open repair for a hostile neck or a long life expectancy, and fenestrated or branched EVAR at an experienced centre. Thoracic: descending aneurysm ≥ 55 mm, complicated and high-risk uncomplicated type B dissection, type B intramural haematoma and penetrating ulcer, and blunt traumatic aortic injury by grade, with left subclavian revascularisation, CSF drainage and open surgery first in heritable aortopathy. After the procedure it reads the endoleak type (I–V) and sac growth into treat-now, reintervene or watch, and gives the lifelong imaging schedule. ESC 2024 beside ACC/AHA 2022.

Upload a report, lab sheet or echo picture to fill this calculator automatically.
Segment
Aneurysm
Anatomy and patient
After the stent graft
Follow-up imaging
Aortic stent graft · EVAR
Enter the AAA diameter
Decision guide
Indication and technique
ESC 2024
  • No repair yet: repair from 55 mm (men) or growth ≥ 10 mm/year
    ESC 2024
    Duplex surveillance; risk-factor control, statin and antiplatelet for atherosclerosis.
ACC/AHA 2022
  • Repair is not recommended below the threshold
    IIIACC/AHA 2022
    Men ≥ 55 mm, women ≥ 50 mm, growth ≥ 5 mm in 6 months or ≥ 10 mm/year, or symptoms.
  • After EVAR: lifelong imaging
    IESC 2024 · ESVS 2024
    CT angiography (or duplex with contrast ultrasound) at 30 days. Low risk (no endoleak, ≥ 10 mm seal at both ends, no kinks): next imaging at 1 year, then duplex every 1–5 years by risk. Higher risk: CT or duplex at 1 year and yearly. Plain X-ray for stent fracture or migration in long-term follow-up.
  • Medical therapy
    ESC 2024 · ACC/AHA 2022
    BP < 130/80 mmHg (dissection: < 120/80 mmHg with a beta-blocker), statin and single antiplatelet for atherosclerotic disease, stop smoking.
Print / Save PDF: opens the print dialog with a table of the inputs and result; choose Save as PDF to keep a file. Made on this device only; nothing is uploaded.